Doctor Blade Application
 Print Document   
 
Roll Location Roll Materials Blade Materials
(Machine speed over 600 m/min)
Working
angle (θ)
Advisable Blade
Pressure N/m
           Normal Maximum
Breast Rolls

 

Rubber(4 - 20 P&J) LA1 – LA3 – LB7 200 - 250 80 120
Hard Rubber (0-3 P&J) LA1 – LA3 – LB7 250 80 130
Black Diamond.

 

LB5 – LB7

 

250

 

80

 

130

 

           
Wire Rolls
       &
Felt Rolls

Hard Rubber (0-3 P&J) LA1 – LA3 – LB7 250 80 110
Black Diamond LB5 – LB7 250 80 110
Beltex LA1 – LA3 250 80 110
Copper/Bronze LA3 – LB5 250 80 110
Stainless Steel

 

LB5 – LA3 – LB7

 

250

 

80

 

110

 

           
Press Rolls

 

Dynarock LB7 – LB3 250 - 300 170 350
Rubber (4-20 P&J) LA1 – LB7 200 - 250 100 150
Hard Rubber (0-3 P&J) LC1 – LB3 – LB7– LB1 250 - 300 170 300
Granite LMO – L18 – LB7 – LB3 – LB1 250 - 300 280 400
Microrock LB7 – LB3 250 200 350
Ceramic LC4 – LC1 – LB1 250 200 300
Stonite

 

LB3 – LB7

 

250

 

230

 

270

 

           
Grooved venta-nip

 

Rubber ( 0-10 P&J ) LA1 – LA3 150 - 250 50 - 90 120
Polyurethane

 

LA1 – LA3

 

150 - 250

 

50 - 90

 

90

 

           
Dryers
 

MG Cylinder

 
Size Press

 
Cooling Cylinder

 

Micro mate LB7 – LB3 250 100 160
Cast Iron LB7 – LBZ – L13 – LBR 250 - 300 160 450
Chrome LB7 – LB5 – LB1 250 - 300 130 170
Steel LB7 – LBZ – LMO 250 - 300   80 180
Hard Rubber( 0 – 3P&J) LB3 – LB7 150 - 300   90 160
Bronze/Chrome Coated LB7 – LB3 – LB5  250   90 160
Copper/Nickel Coated

 

LB7 – LB5

 

250

 

  70

 

140

 

           
Calendar
Stack 

Super Calendar

 

Cast iron Control Crown LB1 – LB7 – LC1 – LB3 300 180 350
Cast iron Intermediate LB1 – LB7 – LMO – LC1 250 - 300   90 200
Polyurethane LB3 – LB7 – LC1 – LB1 270 100 200
Soft Cover Intermediate LB7 – LB1 – LC1 250   90 150
Soft Cover Control Crown

 

LC1 – LB1 – LB7

 

270

 

100

 

160

 

           
Reel Drum Cast Iron/Steel LB7 – LBZ – LB3 250 - 300 145 200
           


The selection of doctor blades for various application as indicated above is linked to the speed of the machine , condition of the rolls , condition of existing doctoring systems and holder , presence of oscillations and lubrication. All the recommendation are indicative and not specific. For proper use of the table which can be modified without any prior notice , it is requested that you contact us for any kind of technical assistance.

* Email to: Levconjaykay@Ljaykay.com  



[ Top 
  

 

| Home |
| Introduction | Design | Quality |
| Application | Service | Enquiry Form |